Reliable measurement methods for the isovolumic relaxation time: comparisons of dual gate Doppler and seven other
Noriko Kimura1, Hiroyuki Toide1, Sayuki Kobayashi2,3
1Center of Medical Ultrasonics, Saitama Medical Center, Dokkyo Medical University, 2-1-50 Minamikoshigaya, Koshigaya City, Saitama, 343-8555, Japan.
Purpose:
Isovolumic relaxation time (IVRT) is a useful indicator of diastolic dysfunction. However, a measurement method for IVRT has not been established. The Dual Gate Doppler method, which can record two separate pulse-wave Doppler signals simultaneously using two sample gates, may be ideal for measuring IVRT. This study aimed to evaluate the accuracy of IVRT measured using conventional methods versus that measured using the Dual Gate Doppler method.
Methods:
A total of 104 patients (mean age 58 ± 21 years, 48 women) were examined using ultrasound equipment with Dual Gate Doppler at our hospital. In addition to Dual Gate Doppler method, IVRTs were measured using seven different methods: pulsed Doppler (PW method), continuous wave Doppler (CW method), and other methods. The IVRT values obtained using the Dual Gate Doppler method were compared with those measured using other methods.
Results:
All IVRTs measured using conventional methods showed a strong correlation with the that measured using the Dual Gate Doppler method. However, there were slight deifferences among the IVRTs depending on the method. The PW method and the PW time difference method using only the PW showed small statistical bias and were not complicated. The IVRT measured using the CW method was significantly longer than that measured using the Dual Gate Doppler method.
Conclusions:
Among the conventional methods, the PW method was the simplest and most practical method for measuring the IVRT in any conditions as arrhythmias. It is important to recognize the characteristics of IVRTs based on the measurement method.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)