Validation of a Deep Learning Algorithm for Continuous, Real-Time Detection of Atrial Fibrillation Using a Wrist-Worn
Ming-Zher Poh1, Anthony J Battisti2, Li-Fang Cheng1
1Verily Life Sciences South San Francisco CA.
Background:
Wearable devices may be useful for identification, quantification and characterization, and management of atrial fibrillation (AF). To date, consumer wrist-worn devices for AF detection using photoplethysmography-based algorithms perform only periodic checks when the user is stationary and are US Food and Drug Administration cleared for prediagnostic uses without intended use for clinical decision-making. There is an unmet need for medical-grade diagnostic wrist-worn devices that provide long-term, continuous AF monitoring.
Methods And Results:
We evaluated the performance of a wrist-worn device with lead-I ECG and continuous photoplethysmography (Verily Study Watch) and photoplethysmography-based convolutional neural network for AF detection and burden estimation in a prospective multicenter study that enrolled 117 patients with paroxysmal AF. A 14-day continuous ECG monitor (Zio XT) served as the reference device to evaluate algorithm sensitivity and specificity for detection of AF in 15-minute intervals. A total of 91 857 intervals were contributed by 111 subjects with evaluable reference and test data (18.3 h/d median watch wear time). The watch was 96.1% sensitive (95% CI, 92.7%-98.0%) and 98.1% specific (95% CI, 97.2%-99.1%) for interval-level AF detection. Photoplethysmography-derived AF burden estimation was highly correlated with the reference device burden (R2=0.986) with a mean difference of 0.8% (95% limits of agreement, -6.6% to 8.2%).
Conclusions:
Continuous monitoring using a photoplethysmography-based convolutional neural network incorporated in a wrist-worn device has clinical-grade performance for AF detection and burden estimation. These findings suggest that monitoring can be performed with wrist-worn wearables for diagnosis and clinical management of AF.
Registration Information:
URL: https://www.clinicaltrials.gov; Unique identifier: NCT04546763.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation