[Design of Portable Noninvasive Positive Pressure Ventilator System Based on Threshold Trigger of Flow Rate Change]
Xin Wang1, Qin Yuan1, Hangduo Niu2
1School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, 611731.
Abstract:
In order to effectively treat respiratory diseases, a non-invasive positive pressure ventilator system is designed, the overall structure design of the system is proposed, and the hardware construction is completed. The breathing state of the patient is identified by the threshold triggering method of the flow rate of change, and the calculation of the flow rate of change is realized by the least squares method. At the same time, the breathing parameters are calculated in real time according to the flow-time and pressure-time characteristic curves. In addition, CMV, CPAP, BiPAP and PSV ventilation modes are also implemented. Finally, the parameter measurement accuracy and ventilation mode setting tests are carried out. The results show that the calculation of key breathing parameters provided by the system meets the relevant standards, and supports the stable output of 4 ventilation modes at the same time, provides breathing treatment for patients, and meets the basic functional requirements of the ventilator.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...