Related Experiment Video
Updated: Jul 15, 2025

Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
Published on: November 7, 2019
Electrical-mechanical dynamical coupling between electrocardiographic and photoplethysmographic signals during
Shuxin Chen1, Lijun Jiang2, Feng Xu2
1Institute of Intelligent Medical Engineering, School of Control Science and Engineering, Shandong University, Jinan, China.
Background And Objective:
Cardiac arrest (CA) remains a significant cause of death and disability. High-quality cardiopulmonary resuscitation (CPR) can improve the survival rate of CA. A challenging issue is to find physiological indicators for screening and evaluating the cardiovascular function associated with CPR. This study aimed to investigate the electrical-mechanical dynamic coupling between electrocardiographic (ECG) and photoplethysmographic (PPG) signals for indicating cardiovascular function in the progress of CPR.
Method:
The ECG and PPG signals were simultaneously collected from a porcine CA model (n = 10) induced by ventricular fibrillation, and were further divided into four periods: Baseline, CA, CPR, and recovery of spontaneous circulation (ROSC). Recurrence quantitative analysis (RQA) was applied to examine the nonlinear dynamics of the ECG and PPG signals individually, and cross recurrence quantitative analysis (CRQA) was used to examine the ECG-PPG dynamical coupling.
Results:
The CA influenced the dynamic patterns of electrical and mechanical activities and the electrical-mechanical coupling, which can be observed from the reduced entropy (ENTR) (p < 0.01), reduced determinism (DET) (p < 0.01) and reduced trapping time (TT) (p < 0.01) at CA compared to Baseline. The recurrence rate (RR), ENTR, DET, and TT at CPR were significantly lower than the parameters at ROSC but higher than those at CA.
Conclusions:
The electrical-mechanical dynamical coupling was sensitive to CPR and able to reflect the changes in cardiac function in the process of CPR.
More Related Videos
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiopulmonary Resuscitation III: AED Use
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation IV: Pharmacological Management