Related Experiment Video
Updated: Jul 15, 2025

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
High-definition blood flow imaging improves quantification of left ventricular volumes and ejection fraction
Francisco Gama1,2, Pedro Custódio1,3, Aliki Tsagkridi1
1St Bartholomew's Hospital, West Smithfield, London, EC1A 7BE, UK.
Aims:
The accuracy and reproducibility of echocardiography to quantify left ventricular ejection fraction (LVEF) is limited due to image quality. High-definition blood flow imaging is a new technique which improves cavity delineation without the need for medication or intravenous access. We sought to examine the impact of high-definition blood flow imaging on accuracy and reproducibility of LV systolic function assessment.
Methods And Results:
Prospective observational study of consecutive patients undergoing 2D and 3D transthoracic echocardiography (TTE), high-definition blood flow imaging, and cardiac magnetic resonance (CMR) within 1 h of each other. Left ventricular systolic function characterized by left ventricular end-systolic volumes and left ventricular end-diastolic volumes and LVEF were measured. Seventy-six patients were included. Correlation of 2D TTE with CMR was modest (r = 0.68) with a worse correlation in patients with three or more segments not visualized (r = 0.58). High-definition blood flow imaging was feasible in all patients, and the correlation of LVEF with CMR was excellent (r = 0.88). The differences between 2D, high-definition blood flow, and 3D TTE compared to CMR were 5 ± 9%, 2 ± 5%, and 1 ± 3%, respectively. The proportion of patients where the grade of LV function was correctly classified improved from 72.3% using 2D TTE to 92.8% using high-definition blood flow imaging. 3D TTE also had excellent correlation with CMR (r = 0.97) however was only feasible in 72.4% of patients.
Conclusion:
High-definition blood flow imaging is highly feasible and significantly improves the diagnostic accuracy and grading of LV function compared to 2D echocardiography.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...