Related Experiment Video
Updated: Jul 15, 2025

Treatment of Facial Deformities using 3D Planning and Printing of Patient-Specific Implants
Published on: May 23, 2020
Mandibular Titanium Miniplates Change the Biomechanical Behaviour of the Mandible in the Case of Facial Trauma: A
Nicolas Graillon1,2, Jean-Marc Foletti1,2, Yves Godio-Raboutet1
1Laboratoire de Bioméchanique Appliquée (LBA), Gustave Eiffel University/Aix-Marseille University, 13015 Marseille, France.
Abstract:
Our study aimed to compare the biomechanical behaviour of mandibles with or without titanium miniplates when subjected to an impact after bone healing using a finite element model (FEM) of the human mandible. We simulated mandibular trauma on an FEM of a human mandible carrying or not two parasymphyseal miniplates and applying a concentrated force of 2000 N to four different areas, including the insertion area, the area straddling the edge of the miniplates and the adjacent bone, at a distance from the miniplates on the symphysis, and on the basilar border of the mandible below the miniplates. Then, we compared the Von Mises stress distributions between the two models. In the case of an impact on the miniplates, the maximum Von Mises stress occurred in two specific areas, on the cortical bone at the posterior border of the two miniplates at a distance from the impact, while in the model without miniplates, the Von Mises stresses were homogenously distributed in the impact area. The presence of titanium miniplates in the case of trauma affects the biomechanical behaviour of the mandible and could cause more complex fractures. We recommend informing patients of this potential risk.