A Study on the Effect of Temperature Variations on FPGA-Based Multi-Channel Time-to-Digital Converters
Awwad H Alshehry1, Saleh M Alshahry1, Abdullah K Alhazmi1
1Department of Electrical and Computer Engineering, University of Dayton, 300 College Park, Dayton, OH 45469, USA.
Abstract:
We describe a study on the effect of temperature variations on multi-channel time-to-digital converters (TDCs). The objective is to study the impact of ambient thermal variations on the performance of field-programmable gate array (FPGA)-based tapped delay line (TDL) TDC systems while simultaneously meeting the requirements of high-precision time measurement, low-cost implementation, small size, and low power consumption. For our study, we chose two devices, Artix-7 and ProASIC3L, manufactured by Xilinx and Microsemi, respectively. The radiation-tolerant ProASIC3L device offers better stability in terms of thermal sensitivity and power consumption compared to the Artix-7. To assess the performance of the TDCs under varying thermal conditions, a laboratory thermal chamber was utilized to maintain ambient temperatures ranging from -75 to 80 °C. This analysis ensured a comprehensive evaluation of the TDCs' performance across a wide operational range. By utilizing the Artix-7 and ProASIC3L devices, we achieved root mean square (RMS) resolution of 24.7 and 554.59 picoseconds, respectively. Total on-chip power of 0.968 W was achieved using Artix-7, while 1.997 mW of power consumption was achieved using the ProASIC3L device. We worked to determine the temperature sensitivity for both FPGA devices, which could help in the design and optimization of FPGA-based TDCs for many applications.
Related Concept Videos
Effect of Temperature Change on Reaction Rate
Effects of Temperature on Free Energy
Temperature Dependence on Reaction Rate
Atoms, molecules, or ions must collide before they can react with each other. Atoms must be close together to form chemical bonds. This premise is the basis for a theory that explains many observations regarding chemical kinetics, including factors affecting reaction rates.
The collision theory is based on the postulates that (i) the reaction rate is proportional to the rate of reactant collisions, (ii) the reacting species collide in an orientation allowing contact between...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...