Related Experiment Video
Updated: Jul 15, 2025
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)
Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury
Published on: November 9, 2018
Performance Analysis of Six Semi-Automated Tumour Delineation Methods on [18F] Fluorodeoxyglucose Positron Emission
Francesco Bianconi1, Roberto Salis2, Mario Luca Fravolini1
1Department of Engineering, Università degli Studi di Perugia, Via Goffredo Duranti 93, 06125 Perugia, Italy.
Abstract:
Background. Head and neck cancer (HNC) is the seventh most common neoplastic disorder at the global level. Contouring HNC lesions on [18F] Fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scans plays a fundamental role for diagnosis, risk assessment, radiotherapy planning and post-treatment evaluation. However, manual contouring is a lengthy and tedious procedure which requires significant effort from the clinician. Methods. We evaluated the performance of six hand-crafted, training-free methods (four threshold-based, two algorithm-based) for the semi-automated delineation of HNC lesions on FDG PET/CT. This study was carried out on a single-centre population of n=103 subjects, and the standard of reference was manual segmentation generated by nuclear medicine specialists. Figures of merit were the Sørensen-Dice coefficient (DSC) and relative volume difference (RVD). Results. Median DSC ranged between 0.595 and 0.792, median RVD between -22.0% and 87.4%. Click and draw and Nestle's methods achieved the best segmentation accuracy (median DSC, respectively, 0.792 ± 0.178 and 0.762 ± 0.107; median RVD, respectively, -21.6% ± 1270.8% and -32.7% ± 40.0%) and outperformed the other methods by a significant margin. Nestle's method also resulted in a lower dispersion of the data, hence showing stronger inter-patient stability. The accuracy of the two best methods was in agreement with the most recent state-of-the art results. Conclusions. Semi-automated PET delineation methods show potential to assist clinicians in the segmentation of HNC lesions on FDG PET/CT images, although manual refinement may sometimes be needed to obtain clinically acceptable ROIs.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET