Background:
Bone-subtraction computed tomography angiography (CTA) (BSCTA) is a new technique designed to overcome the limitation of three-dimensional CTA, where the vessels surrounded by bone and calcification can be obscured. An optimal contrast CT protocol for intracranial artery visualization with BSCTA has yet to be established in dogs.
Objectives:
The purpose of this study was to determine the optimal contrast protocol of CTA for visualizing intracranial artery using an automatic bone-subtraction technique in dogs.
Methods:
Brain CTA was performed four times for each of nine healthy beagle dogs to cover all the contrast protocols: two different contrast iodine concentrations (300 and 370 mgI/mL) and two different contrast media injection rates (2 and 4 mL/s). Bone removal post-processing was performed automatically by subtracting the non-enhanced CT data from the contrast CT data using a dedicated workstation. The bone-subtracted intracranial vessels were analysed for quantitative and qualitative evaluation.
Results:
Quantitative evaluation showed significantly higher CT attenuation values for the group with a 370 mgI/mL iodine content at a rate of 4 mL/s than the two groups with a 300 mgI/mL iodine content at the rates of 2 and 4 mL/s (p < 0.001). Qualitative assessment revealed significantly higher mean scores for the 370 mgI/mL groups than the 300 mgI/mL groups and significantly higher mean scores for the 4 mL/s groups than the 2 mL/s groups (p < 0.05).
Conclusions:
The optimal contrast protocol for BSCTA suggests that high iodine material concentration and high injection rate should be used for strong arterial attenuation and great visualization of the intracranial arterial structure in dogs.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography