Related Experiment Video
Updated: Jul 15, 2025

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Evaluation of the effectiveness of non-contact respiration rate detection for post-crash care application
Jacob T Valente1, Sparsh Jain1, Arush Amin2
1Department of Biomedical Engineering and Mechanics, Virginia Tech, Blacksburg, USA; Virginia Tech Transportation Institute, Virginia Tech, Blacksburg, USA.
Abstract:
The ability of emergency medical services (EMS) personnel to understand the mortality and morbidity risks associated with different injuries is critical for effective motor vehicle collision (MVC) post-crash care. Interwoven with this ability is the practice of accurate and efficient patient triage. Triage allows EMS to gain a better understanding of the physiological and physical status of a patient and their injuries, with the intention of identifying additional resources needed, potential treatment options, and the most appropriate care destination. An interactive, in-vehicle triage system, based on the Simple Triage and Rapid Treatment protocol, under development could lead to improved MVC triage accuracy and efficiency. As a component of that system, this study examines the effectiveness of using non-contact respiration rate detection technologies integrated into a vehicle cabin. The selected technologies included ultrasonic respiration detection, thermal respiration detection, and pressurebased detection which were all compared against data collected from a respiration belt. All technologies were integrated into a 2015 Ford Taurus. Testing took place inside the running vehicle and considered occupant weight, cabin temperature, occupant clothing weight, and environmental sound as experimental factors. Respiration rate was then calculated using a 30-second sliding window where the means and standard deviations were used to compare the accuracy and precision of the sensor systems across the experimental factors. The sensor type, temperature level, and sound level main effects significantly influenced the mean respiration rate. For the standard deviation of respiration rate, significant effects were found for the sensor type, sound level, and clothing weight main effects. Among the tested sensor systems, the pressure sensor was found to best match the accuracy and precision of the respiration belt. Future work should address limitations in the approach used for this proof-of-concept work.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Cardiopulmonary Resuscitation I: Adult
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Acute Respiratory Failure-IV
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...

