Related Experiment Video
Updated: Jul 15, 2025

Surgical Retrieval, Isolation and In vitro Expansion of Human Anterior Cruciate Ligament-derived Cells for Tissue Engineering Applications
Published on: April 30, 2014
Is Intraoperative Bleeding Control Useful After Tourniquet Release in Arthroscopic Anterior Cruciate Ligament
Oğuzhan Çimen1, Ibrahim Azboy2, Bertan Cengiz3
1Orthopaedics and Traumatology, Medistanbul Hospital, Istanbul, TUR.
Abstract:
Background Arthroscopic anterior cruciate ligament (ACL) reconstruction is a common orthopedic surgery, and rehabilitation is very important to achieve successful postoperative results. Postoperative hemarthrosis causes pain and limitation of movement, which prolongs the rehabilitation period. For these reasons, various strategies are used to reduce hemarthrosis in patients undergoing ACL reconstruction. This study aimed to evaluate the effect of bleeding control after releasing the tourniquet in ACL reconstruction surgery on the amount of hemarthrosis and pain in the postoperative period. Methodology A total of 60 patients who underwent arthroscopic single-bundle ACL reconstruction were enrolled in this prospective randomized control study. Bleeding control with the radiofrequency (RF) probe after releasing the tourniquet was done at the end of the arthroscopic ACL reconstruction in 30 patients (coagulation group) while bleeding control was not done for the other 30 patients (control group). Both groups were compared in terms of the degree of hemarthrosis using the Coupens and Yates classification in the early postoperative period and the degree of pain using the Visual Analog Scale (VAS) score and postoperative complications. Results In both groups, isolated ACL reconstruction was performed in 10 patients, additional partial meniscectomy in three patients, and additional arthroscopic meniscus repair in 17 patients. There was no statistically significant difference between the coagulation and control groups in terms of VAS (p > 0.05) and the degree of hemarthrosis (p > 0.05). Although the duration of tourniquet application was similar in both groups (p = 0.78), the duration of anesthesia was significantly longer in the coagulation group (p = 0.001). There was no significant difference between the groups in terms of postoperative complications. Conclusions Bleeding control with the RF probe after tourniquet release does not yield superior outcomes. More research with larger populations is needed to confirm these findings.
More Related Videos
05:07Author Spotlight: Implementing the Enhanced Recovery After Surgery Concept in Rehabilitation Following Anterior Cruciate Ligament Reconstruction
Published on: March 1, 2024
05:44Author Spotlight: Double Posteromedial Approach for Treating Posterior Cruciate Ligament Cysts
Published on: October 20, 2023