Related Experiment Video
Updated: Jul 15, 2025

Analysis of Raw and Processed Cyperi Rhizoma Samples Using Liquid Chromatography-Tandem Mass Spectrometry in Rats with Primary Dysmenorrhea
Published on: December 23, 2022
Quality testing of mifepristone and misoprostol in 11 countries
Jason Bower1, Lester Chinery2, Alessandra Fleurent2
1Independent Consultant, London, UK.
Objective:
Previous studies have demonstrated quality concerns with misoprostol. Mifepristone, however, has not been extensively assessed for quality. Between 2020 and 2021, Concept Foundation and the International Planned Parenthood Federation conducted a study to determine the quality of these medical abortion drugs in low- and middle-income countries (LMIC).
Methods:
The collection of batch samples of misoprostol and mifepristone was carried out by trained sampling agents in selected LMIC. Single drug packs and combipacks were sampled. A World Health Organization prequalified laboratory conducted testing method verifications and subsequent sample analysis. Tests included identification, assay, related substances, and content uniformity for misoprostol, and identification, assay, related substances, and dissolution for mifepristone.
Results:
Samples were collected from Burkina Faso, Cambodia, Democratic Republic of Congo, India, Kyrgyzstan, Moldova, Nepal, Nigeria, Pakistan, Uganda and Vietnam. Sixty-four pooled batch samples were tested, consisting of 31 combipacks, 26 misoprostol-only and seven mifepristone-only products. Overall, 54.7% of samples were non-compliant with one or more of the specifications, representing 51.6% of combipack products, 57.1% of misoprostol tablets analyzed and 23.7% of mifepristone tablets. One falsified misoprostol-only product was found.
Conclusion:
The present study confirms that a significant problem still exists in relation to the quality of medical abortion drugs in LMIC. For misoprostol, our findings suggest that historical concerns around primary packaging may have been largely resolved but that manufacturing processes for both finished product and active pharmaceutical ingredient need to be improved. The present study also provides evidence of mifepristone quality issues.
Related Concept Videos
Drugs for Peptic Ulcer Disease: Prostaglandin Analogs as Mucosal Protective Agents
Non-steroidal anti-inflammatory drugs (NSAIDs) can induce peptic ulcers by inhibiting cyclooxygenase, decreasing...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Drug Regulation
Preclinical Development: Overview