Related Experiment Video
Updated: Jul 15, 2025

Handheld Metal Detector Screening for Metallic Foreign Body Ingestion in Children
Published on: September 11, 2018
The Evaluation of Serum Metal Ion Levels and Metallosis in Graduated Patients With Magnetically Controlled Growing
Flavia Alberghina1, Robin McManus, Cillian Keogh
1Department of Orthopaedics, Children's Health Ireland (CHI) at Crumlin, Crumlin, Dublin, Ireland.
Background:
Magnetically controlled growing rods (MCGR) aim to control curve progression while limiting surgical burden in children with early-onset scoliosis. Systemic and local distribution of metal debris has been documented in children with spinal implants. The aim of the study was to assess serum metal ion levels and local metal debris-related changes at the conclusion of MCGR treatment.
Methods:
Between February 2019 and September 2022, all patients who had a conversion to definitive fusion at the completion of MCGR treatment in our institution were invited to participate in this study. Consenting patients had serum metal ion levels drawn (titanium, cobalt, and chromium) and histologic analyses of peri-implant tissue samples.
Results:
We enrolled 24 children who underwent definitive fusion post-MCGR treatment for early-onset scoliosis. The average age at definitive fusion was 13.3 years (range: 11 to 17 y). The average length of MCGR treatment was 4.8 years (range: 1.5 to 6.8 y). At the end of the MCGR treatment, 23 (96%) patients had elevated serum metal ion levels. Mean serum titanium levels were 165.4 nmol/L (range: 30 to 390 nmol/L), mean serum cobalt levels were 4.6 nmol/L (range: 1.2 to 14 nmol/L), and mean serum chromium levels were 14 nmol/L (range: 2.4 to 30 nmol/L). Peri-implant soft tissue histologic analysis demonstrated local metal debris and foreign body reactions in all patients.
Conclusions:
At the completion of MCGR treatment, the majority of patients demonstrate elevated serum metal ion levels and local metal debris-related peri-implant soft tissue changes. Although there is no current literature to suggest these findings are harmful, further research as to the clinical significance is required.
Level Of Evidence:
Level IV.
More Related Videos
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
07:26Metal-Limited Growth of Neisseria gonorrhoeae for Characterization of Metal-Responsive Genes and Metal Acquisition from Host Ligands
Published on: March 4, 2020
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Complexometric Titration: Overview