Related Experiment Video
Updated: Jul 15, 2025

Self-Nanoemulsification of Healthy Oils to Enhance the Solubility of Lipophilic Drugs
Published on: July 27, 2022
Hansen Solubility Parameters and QbD-Oriented HPLC Method Development and Validation for Dermatokinetic Study of a
Afzal Hussain1, Mohammad A Altamimi1, Mohhammad Ramzan2
1Department of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia.
Abstract:
Miconazole (MCZ) is a potential antifungal drug to treat skin infections caused by Candida, Tinea pedis (athlete's foot fungal infection), Tinea cruris (jock itching in the groin and buttocks), and Tinea corporis (red scaly rash on the skin). The current study focused on Hansen parameter-based solvent selection (HSPiP software) and method development optimization using an experimental design tool for sensitive, accurate, reproducible, economic, rapid, robust, and precise methodology to quantify MCZ in rat plasma. Moreover, a Taguchi design was used for screening two independent factors (flow rate and ACN content). Quality by design (QbD) was employed to optimize and identify the right ratio of mobile phase composition and its impact on the peak and retention time. The elution of MCZ was achieved using methanol and acetonitrile (15:85 v/v ratio) at a retention time of 6 min and optimal flow rate (1 mL/min). Finally, the method was validated based on accuracy, precision, linearity, selectiveness, and high recovery at varied concentrations as per the International Council for Harmonization (ICH) guidelines. The method was linear (r2 = 0.999) over the explored concentration range (250-2000 ng/mL) at 270 nm detection wavelength. The optimized method was used to quantify in vivo pharmacokinetic (PK) study after transdermal application of MCZ-loaded formulations (MCNE11, MNE11, MCZ-Sol, and MCZ-MKT). HSP-oriented solvent selection and quality by design-based optimized process variables and composition in the optimized analytical methodology were quite convincing and have been a cutting-edge MCZ analysis method so far. The validated method was robust, economic, and rapid with high specificity and selectivity.
More Related Videos
11:07Visualizing and Quantifying Pharmaceutical Compounds within Skin using Coherent Raman Scattering Imaging
Published on: November 24, 2021
06:02Author Spotlight: Development and Evaluation of a Cationic Nanoemulsion-Encapsulated Retinoic Acid System for Mucosal Vaccination
Published on: February 23, 2024