Related Experiment Video
Updated: Jul 15, 2025

A Suction Blister Protocol to Study Human T-cell Recall Responses In Vivo
Published on: August 11, 2018
Blister fluid as a cellular input for ex vivo diagnostics in drug-induced severe cutaneous adverse reactions improves
Andrew Awad1, Effie Mouhtouris1, Catriona Vi Nguyen-Robertson2
1Centre for Antibiotic Allergy and Research, Department of Infectious Diseases, Austin Hospital, Heidelberg, Australia.
Background:
Drug-induced severe cutaneous adverse reactions (SCARs) are presumed T-cell-mediated hypersensitivities associated with significant morbidity and mortality. Traditional in vivo testing methods, such as patch or intradermal testing, are limited by a lack of standardization and poor sensitivity. Modern approaches to testing include measurement of IFN-γ release from patient PBMCs stimulated with the suspected causative drug.
Objective:
We sought to improve ex vivo diagnostics for drug-induced SCARs by comparing enzyme-linked immunospot (ELISpot) sensitivities and flow cytometry-based intracellular cytokine staining and determination of the cellular composition of separate samples (PBMCs or blister fluid cells [BFCs]) from the same donor.
Methods:
ELISpot and flow cytometry analyses of IFN-γ release were performed on donor-matched PBMC and BFC samples from 4 patients with SCARs with distinct drug hypersensitivity.
Results:
Immune responses to suspected drugs were detected in both the PBMC and BFC samples of 2 donors (donor patient 1 in response to ceftriaxone and case patient 4 in response to oxypurinol), with BFCs eliciting stronger responses. For the other 2 donors, only BFC samples showed a response to meloxicam (case patient 2) or sulfamethoxazole and its 4-nitro metabolite (case patient 3). Consistently, flow cytometry revealed a greater proportion of IFN-γ-secreting cells in the BFCs than in the PBMCs. The BFCs from case patient 3 were also enriched for memory, activation, and/or tissue recruitment markers over the PBMCs.
Conclusion:
Analysis of BFC samples for drug hypersensitivity diagnostics offers a higher sensitivity for detecting positive responses than does analysis of PBMC samples. This is consistent with recruitment (and enrichment) of cytokine-secreting cells with a memory/activated phenotype into blisters.
Related Concept Videos
Inflammatory Response II: Inflammatory Exudate and Tissue Repair
The typical wound exudate is odorless, transparent, straw-colored, thin, and watery. Exudate, however, can differ depending on the state of wound healing. Likewise, the...
Clinical Applications of Epidermal Stem Cells