Background:
Minimally invasive surfactant therapy (MIST), a method of surfactant delivery via a thin catheter during spontaneous breathing, is an increasingly popular alternative to intubation and surfactant administration. Recently, purpose-built catheters for MIST received regulatory approval in Canada and became available for use. However, procedural success and user experience with such catheters have not been described.
Methods:
This retrospective cohort study included neonates who received MIST using purpose-built catheters between January 1, 2021, and March 31, 2022. Two types of purpose-built catheters were used in this period - SurfCath™ and BLEScath™. Procedural success, number of attempts, and adverse events in neonates receiving MIST via the two catheters were compared using chi-square or Fisher's tests. User experience was described using an ease-of-use scale.
Results:
Thirty-seven neonates met eligibility criteria; 22 received MIST via SurfCath™, whereas 15 received MIST via BLEScath™. Success rates were 91% in SurfCath™ and 93% in BLEScath™ (P> 0.994). Failed attempts were lower in SurfCath™ (23%) in comparison to BLEScath™ (33%), but the difference was not statistically significant (P=0.708). Among operators, 90% found SurfCath™ very easy/relatively easy to use compared to 43% of users reflecting the same degree of use with BLEScath™ (P=.021). There was no difference in adverse events.
Conclusion:
This is the first study in Canada to report MIST with purpose-built catheters. Overall, the success rate was equally high with both catheters. Users subjectively reported higher ease of use with SurfCath™. Commercially available purpose-built catheters should facilitate universal adaptation of the MIST method.
More Related Videos
07:20Lavage-induced Surfactant Depletion in Pigs As a Model of the Acute Respiratory Distress Syndrome ARDS
Published on: September 7, 2016
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...