Assessment of tympanic membrane perforation size using ImageJ software by ENT clinicians of different grades

Bhargavi Chandrasekar1, Kristijonas Milinis1, Natalie Lowe1

  • 1ENT Department, Alder Hey Children's NHS Foundation Trust, Eaton Road, Liverpool, UK.

Insights

ImageJ software offers a more accurate method for measuring paediatric tympanic membrane perforations compared to visual estimation. This digital tool provides consistent results across clinicians of all experience levels, improving diagnostic precision.

Area of Science:

  • Otolaryngology
  • Medical Imaging
  • Pediatric Medicine

Background:

  • Accurate measurement of tympanic membrane perforations is crucial for appropriate clinical management in children.
  • Visual estimation is commonly used but may lack precision.
  • Digital tools offer potential for improved accuracy in otologic assessments.

Purpose of the Study:

  • To compare the accuracy of visual estimation versus ImageJ software calculation for determining tympanic membrane perforation size in paediatric patients.
  • To assess the impact of clinician experience on the accuracy of these measurement methods.

Main Methods:

  • Five otoendoscopic images of paediatric tympanic membrane perforations were selected.
  • Clinicians of varying experience (consultants, registrars, Senior House Officers) performed visual estimations and ImageJ calculations.
  • ImageJ results from a consultant otologist served as the gold standard.

Main Results:

  • ImageJ calculation demonstrated significantly higher accuracy than visual estimation, with a mean difference of 12.16% from the gold standard (p < 0.05).
  • Registrars showed greater accuracy in visual estimation compared to Senior House Officers.
  • No significant differences in ImageJ calculation accuracy were observed between different clinician experience levels.

Conclusions:

  • ImageJ software provides a more accurate and reliable method for measuring tympanic membrane perforation size in children than traditional visual assessment.
  • The accuracy of ImageJ measurements is independent of the clinician's experience level.
  • This finding supports the adoption of ImageJ for standardized and precise evaluation of paediatric tympanic membrane perforations.