Related Experiment Video
Updated: Jul 15, 2025

Deep Vein Thrombosis Induced by Stasis in Mice Monitored by High Frequency Ultrasonography
Published on: April 13, 2018
Periorbital venous stasis may be involved with filler induced malar edema-A duplex ultrasound-imaging-based case
L Schelke1, O Liplavk1, S Cotofana1,2
1Department of Dermatology, Erasmus University Medical Center, Rotterdam, The Netherlands.
Introduction:
Filler injections in the periocular region are regarded as a challenging and advanced maneuver in a high-risk area. Adverse events as malar edema due to filler treatment may occur. To evaluate the possible reasons, the ultrasound images, and medical data of patients that were prospectively referred with malar edema were evaluated.
Materials And Methods:
A total of 17 patients (26 eyes) with malar edema after hyaluronic acid filler treatment were included. All cases were assessed with an 18 MHz linear ultrasound device. Exact location of the filler material was noted. Relations with clinical data were analyzed using chi-square tests.
Results:
Onset of malar edema after treatment showed a wide range from immediate (0 days) to 3 years. Most patients had an early onset N = 13 (76%), a minority showed late onset N = 4 (24%). In 23 eyes, the filler material was found to be located inside the SMAS. In 3 cases filler material was located on the periosteum of the orbital rim. After duplex-ultrasound guided filler removal, restored venous flow could be seen in the superficial and/or deep fatty layer often accompanied by flow piercing through the SMAS. Minutes after treatment, clinical improvement of malar edema was observed.
Conclusion:
Malar edema after by filler treatments in the periocular region may be caused by veno-lymphatic compression by filler deposits.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Ultrasonography
During an ultrasonography procedure, a handheld device called...