Sensitivity and Specificity of Pulse Oximetry for Identification of Peripheral Artery Disease: A Systematic Review
Background:
Lower limb peripheral artery disease (PAD) is associated with poor outcomes including ulceration, gangrene, amputations, and mortality. Clinicians therefore routinely perform point-of-care tests in high-risk populations to identify PAD and subsequently implement cardiovascular management and appropriate interventions. Pulse oximetry has been suggested as a useful adjunct test for identifying PAD.
Objective:
The aim of this systematic review was to determine the sensitivity and specificity of pulse oximetry in the lower limb for identifying PAD.
Methods:
MEDLINE, EMBASE, and CINAHL were searched up until January 10, 2023, to identify studies of sensitivity and specificity of pulse oximetry that used criterion standard diagnostic imaging as a reference standard. Two authors screened articles for inclusion and appraised quality of included studies using the Quality Appraisal for Diagnostic Accuracy Studies, version 2.
Results:
A total of 6371 records were screened, and 4 were included. The included studies had a total of 471 participants, with an age range of 41 to 80.6 years. All studies were cross-sectional and conducted in hospital settings. Sensitivity values for pulse oximetry compared with diagnostic imaging in identifying PAD ranged from 44% to 76%, and specificity values ranged from 85% to 96%. There was no consensus regarding measurement techniques and diagnostic thresholds for pulse oximetry, which precluded meta-analysis.
Conclusions:
There is currently inadequate evidence to support the use of pulse oximetry for identifying PAD. Current evidence suggests that pulse oximetry has low levels of sensitivity and is therefore likely to miss PAD when it is present.
More Related Videos
08:42Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Assessment Sites
Pulse
The pulse serves as a clinical...
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests