Diagnosis of severe anaemia and positive antibody screening as consequences of pre-analytical error
Marta Krygowska-Okrój1, Katarzyna Kurpierz2, Agnieszka Ćwiklińska1
1Medical University of Gdańsk, Department of Clinical Chemistry, Gdańsk, Poland.
The pre-analytical phase is the principal source of errors in laboratory medicine and continues to pose a challenge to laboratory professionals. We present the case of a 73-yearold female patient with a very low hemoglobin level (69 g/L) and positive indirect antiglobulin test result that indicates the key role of phlebotomy as an important error-prone process in which mistakes can have serious consequences for the patient's diagnosis and treatment. We conclude that there is still an urgent and continuous need to provide educational activities for healthcare professionals involved in blood collection, improve blood collection guideline adherence, and eliminate the errors which can affect diagnosis and treatment, thus jeopardising patient safety.
The pre-analytical phase is the principal source of errors in laboratory medicine and continues to pose a challenge to laboratory professionals. We present the case of a 73-yearold female patient with a very low hemoglobin level (69 g/L) and positive indirect antiglobulin test result that indicates the key role of phlebotomy as an important error-prone process in which mistakes can have serious consequences for the patient's diagnosis and treatment. We conclude that there is still an urgent and continuous need to provide educational activities for healthcare professionals involved in blood collection, improve blood collection guideline adherence, and eliminate the errors which can affect diagnosis and treatment, thus jeopardising patient safety.
Related Concept Videos
Blood Typing
Antigens are protein molecules that reside on the surface of red blood cells (RBCs). The ABO and Rh blood typing systems target...
Rh Blood Group
Errors occurring during blood pressure monitoring
Several factors...