An improved algorithm for resolving overlapping peaks in ion mobility spectrometry and its application to the
Xiangyang Hu1,2, Junfei Zhou1,2, Junhui Li2,3
1Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, P. R. China. yujiancheng@nbu.edu.cn.
Abstract:
Despite the popularity of ion mobility spectrometry (IMS) for glycan analysis, its limited structural resolution hinders the effective separation of many glycan isomers. This leads to the overlap of IMS peaks, consequently impacting the accurate identification of glycan compositions. To this end, an improved algorithm, namely second-order differentiation combined with a simulated annealing particle swarm optimization algorithm based on sine adaptive weights (DWSA-PSO), was proposed for the separation of overlapping IMS peaks formed by glycan isomers. DWSA-PSO first performed second-order differentiation to automatically determine the number of components in overlapping peaks and exclude impossible single-peak combinations. It then introduced sinusoidal adaptive weights and a simulated annealing mechanism to improve the algorithm's search capability and global optimization performance, thereby enabling accurate and efficient separation of individual peaks. To evaluate the performance of DWSA-PSO and its application to the separation of glycan isomers, multiple sets of overlapping peaks with different degrees of overlap were simulated, and various types of multi-component overlapping peaks were formed using six disaccharide and four trisaccharide isomers. The experimental results consistently demonstrated that the DWSA-PSO algorithm outperformed both the improved particle swarm optimization (IPSO) algorithm and the dynamic inertia weight particle swarm optimization (DIWPSO) algorithm in terms of separation accuracy, running time, and fitness values. In addition, the DWSA-PSO algorithm was successfully applied to the separation of glycan isomers in malt milk beverage. All these results reveal the capability of the DWSA-PSO algorithm to facilitate the accurate identification of glycan isomers.
More Related Videos
13:06Improved In-gel Reductive β-Elimination for Comprehensive O-linked and Sulfo-glycomics by Mass Spectrometry
Published on: November 20, 2014
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Resolution Mass Spectrometry (HRMS)
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Analyzers: Overview