A Novel Approach to Monitoring Graft Neovascularization in the Human Gingiva
Published on: January 12, 2019
A Novel Doppler Flowmetry Shaft for Postoperative Monitoring after Head and Neck Reconstructive Surgery
Satoshi Onoda1, Toshihiko Satake1, Ryohei Katsuragi1
1From the Department of Plastic and Reconstructive, Aesthetic Surgery, Toyama University Hospital, Toyama, Japan.
Abstract:
Doppler flowmetry is one of the most popular methods of monitoring Doppler signals during reconstructive surgery of the body surface. However, because of the thick and straight structure of the shaft, it is difficult to perform in areas with limited space, such as the oral cavity. We used a new type of Doppler flowmetry shaft to postoperatively monitor the flap in the oral cavity. Compared with conventional Doppler flowmetry, the new type uses a thinner metal probe shaft that can easily be inserted in narrow and limited spaces, such as the oral cavity. Additionally, the tip of the metal probe is gently bent, thereby allowing the Doppler tip to be placed perpendicular to the surface of the skin flap. We used this new type of Doppler flowmetry shaft for 30 patients after head and neck reconstruction using free flap transfer because Doppler signals were difficult to hear using conventional Doppler flowmetry. For all 30 patients, the new Doppler flowmetry shaft was able to monitor free flaps. Vascular thrombosis or vascular spasm occurred in three patients; two patients had inadequate arterial flow caused by vasospasm and arterial thrombus, and one patient had a venous thrombus. These three patients required re-exploration, and all flaps survived. This new type of Doppler flowmetry is simple and noninvasive. Furthermore, it can easily be performed by nonphysician medical personnel, and is useful for monitoring patients after head and neck reconstructive surgery.
More Related Videos
08:05A Pre-clinical Rat Model for the Study of Ischemia-reperfusion Injury in Reconstructive Microsurgery
Published on: November 8, 2019
12:15Optimized System for Cerebral Perfusion Monitoring in the Rat Stroke Model of Intraluminal Middle Cerebral Artery Occlusion
Published on: February 17, 2013
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...