Related Experiment Video
Updated: Jul 14, 2025

Optimize Flue Gas Settings to Promote Microalgae Growth in Photobioreactors via Computer Simulations
Published on: October 1, 2013
Development of a CFD model indicating the quantitative relationship among reactor dimension, bed flow unevenness, and
Ziyu Liu1, Dong Dong2, Jinying Xi1
1Environmental Simulation and Pollution Control State Key Joint Laboratory, School of Environment, Tsinghua University, Beijing, P.R. China.
Abstract:
This study presents a Computational Fluid Dynamics (CFD) based biofiltration model to investigate the airflow distribution and the impact of bed flow unevenness (BFU) on the removal of Volatile Organic Compounds (VOCs) in biofilters. The biofiltration model consists of a gas flow sub-model and a VOCs removal sub-model, which were validated by pilot-scale experiments. The model was used to examine the quantitative relationship among reactor dimensions, including the width to height ratio of the filter bed and empty bed residence time (EBRT), BFU, and performance for VOCs biofilters. Simulation results demonstrate that the flow unevenness index (FUI) of the packing layer changes from 0.06 to 0.48 m2‧s-1 with reactor dimension changes. With an increase in the width to height ratio at a constant EBRT, FUI increases, BFU changes, and flow velocity fluctuation on the cross-section becomes larger, leading to a reduction of about 10% in VOCs removal efficiency. Concentration distribution of VOCs becomes uneven in the horizontal direction. At a constant width to height ratio of the filter bed, an increase in EBRT causes an increase in FUI, leading to a decrease in VOCs removal efficiency. When the width to height ratio is 0.5, velocity fluctuation of filter bed cross-section is small, the concentration of VOCs decreases evenly across the filter bed layer, and FUI is at a low level (0.06-0.11 m2‧s-1).Implication: In this manuscript, a biofiltration model of VOCs biofilter based on CFD has constructed and validated. And the manuscript gave the quantitative relationship among reactor dimension, bed flow unevenness and performance for VOCs biofilters for the first time. This study can lead to enhanced VOCs removal efficiency and improved overall performance of biofilters in practical engineering applications.
Related Concept Videos
Typical Model Studies
Rapidly Varying Flow
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...