Related Experiment Video
Updated: Jul 25, 2026

Echocardiographic Assessment of Cardiac Anatomy and Function in Adult Rats
Published on: December 13, 2019
Establishment of Reference Intervals for Caudal Vena Cava-to-Aorta Ratio Measured Ultrasonographically in Healthy
Anthony Barthélemy1, Julie Combet-Curt1, Adrien Dupanloup2
1Intensive Care Unit (SIAMU), Université de Lyon, VetAgro Sup, APCSe, Marcy l'Etoile, France; Université de Lyon, VetAgro Sup, APCSe, Marcy l'Etoile, France.
Abstract:
The ultrasonographic assessment of the caudal vena cava-to-aorta ratio (CVC:Ao) appears to be a promising method for early recognition of alterations of intravascular volume status in veterinary medicine. The primary objective of this study was to establish the reference intervals of the CVC:Ao ratio with ultrasound in nonsedated healthy dogs. Secondary objectives were to determine the influence of the respiratory cycle and to evaluate correlations between ultrasonographic measurements, signalment and physical exam findings. Ultrasonographic measurements of Ao and CVC diameters were successfully obtained for all sixty dogs included. No evidence of a difference was observed between the measurements of Ao and CVC diameters, and CVC:Ao ratio between inspiration and expiration (P = .373, P = .318, and P = .537, respectively). The reference interval for CVC:Ao ratio (95% CI), generated from US measurements performed at any moment of the respiratory cycle was defined as 0.93 (0.91-0.95) -1.32 (1.30-1.34). The CVC:Ao ratio was significantly negatively correlated with age (r = -0.341, P = .008) and positively correlated with respiratory rate (r = 0.423, P < .001), but not with heart rate (P = .573) or arterial systolic blood pressure (P = .166). A low inter- and intraoperator variability in repeated measurements was observed for each operator and between operators. The ultrasonographic measurement of the CVC:Ao ratio appears as a simple method with low inter- and intraoperator variability using the ultrasonographic protocol described in the current study. With the reference interval established in the present study in healthy nonsedated dogs, further studies should evaluate the utility of this simple method in assessing and monitoring volume status in hypo- and hypervolemic dogs.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure

