Visible and near-infrared spectroscopic determination of sugarcane chlorophyll content using a modified wavelength
Pauline Ong1, Jinbao Jian2, Xiuhua Li3
1College of Mathematics and Physics, Center for Applied Mathematics of Guangxi, Guangxi Minzu University, Nanning 530006, China; Faculty of Mechanical and Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Batu Pahat, Johor.
Abstract:
Spectroscopy in the visible and near-infrared region (Vis-NIR) region has proven to be an effective technique for quantifying the chlorophyll contents of plants, which serves as an important indicator of their photosynthetic rate and health status. However, the Vis-NIR spectroscopy analysis confronts a significant challenge concerning the existence of spectral variations and interferences induced by diverse factors. Hence, the selection of characteristic wavelengths plays a crucial role in Vis-NIR spectroscopy analysis. In this study, a novel wavelength selection approach known as the modified regression coefficient (MRC) selection method was introduced to enhance the diagnostic accuracy of chlorophyll content in sugarcane leaves. Experimental data comprising spectral reflectance measurements (220-1400 nm) were collected from sugarcane leaf samples at different growth stages, including seedling, tillering, and jointing, and the corresponding chlorophyll contents were measured. The proposed MRC method was employed to select optimal wavelengths for analysis, and subsequent partial least squares regression (PLSR) and Gaussian process regression (GPR) models were developed to establish the relationship between the selected wavelengths and the measured chlorophyll contents. In comparison to full-spectrum modelling and other commonly employed wavelength selection techniques, the proposed simplified MRC-GPR model, utilizing a subset of 291 selected wavelengths, demonstrated superior performance. The MRC-GPR model achieved higher coefficient of determination of 0.9665 and 0.8659, and lower root mean squared error of 1.7624 and 3.2029, for calibration set and prediction set, respectively. Results showed that the GPR model, a nonlinear regression approach, outperformed the PLSR model.
More Related Videos
Related Concept Videos
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Light Acquisition
UV–Vis Spectroscopy: Woodward–Fieser Rules
UV–Vis Spectroscopy of Conjugated Systems
One of the factors influencing λmax is the extent...
UV–Vis Spectrometers
IR and UV–Vis Spectroscopy of Aldehydes and Ketones


