Related Experiment Video
Updated: Jul 14, 2025

Semi-automated Optical Heartbeat Analysis of Small Hearts
Published on: September 16, 2009
Using beat-to-beat heart signals for age-independent biometric verification
Moran Davoodi1,2, Adam Soker1, Joachim A Behar1
1Biomedical Engineering Faculty, Technion-IIT, Haifa, Israel.
Abstract:
Use of non-stationary physiological signals for biometric verification, reduces the ability to forge. Such signals should be simple to acquire with inexpensive equipment. The beat-to-beat information embedded within the time intervals between consecutive heart beats is a non-stationary physiological signal; its potential for biometric verification has not been studied. This work introduces a biometric verification method termed "CompaRR". Heartbeat was extracted from longitudinal recordings from 30 mice ranging from 6 to 24 months of age (equivalent to ~ 20-75 human years). Fifty heartbeats, which is close to resting human heartbeats in a minute, were sufficient for the verification task, achieving a minimal equal error rate of 0.21. When trained on 6-month-old mice and tested on unseen mice up to 18-months of age (equivalent to ~ 50 human years), no significant change in the verification performance was noted. Finally, when the model was trained on data from drug-treated mice, verification was still possible.
More Related Videos
08:22Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
08:12Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Related Concept Videos
Special considerations while measuring pulse
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...