Related Experiment Video
Updated: Jul 14, 2025

Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds
Published on: November 6, 2015
Can the inner eye canthus temperature be used as an alternative method to measure core temperature in sleep-deprived
Carlos Magno Amaral Costa1, Fernanda Veruska Narciso2, Valdênio Martins Brant3
1Exercise Physiology Laboratory, Instituto Federal do Sudeste de Minas Gerais, Campus Rio Pomba, Rio Pomba, Minas Gerais, Brazil; Center for Psychobiology and Exercise Studies, Department of Sports, Physical Education School, Physiotherapy and Occupational Therapy, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil.
Abstract:
Core temperature is used in several situations, including studies on biological rhythms and circadian markers of physical performance. Measuring the inner eye canthus (Tco) temperature is a method proposed to identify core temperature, but it has shown little concordance in physical exercise situations and has not yet been used in studies with measurements taken throughout the day. The objective of this study was to compare the measurements and daily behavior of Tco obtained by infrared thermography with rectal temperature (Tre) during a prolonged waking protocol. Eleven male individuals participated in the study, who remained in the laboratory for at least 38 h using an actigraph to determine the wakefulness time and were monitored during the entire period. The Tre and Tco measurements were performed every 3 h. The ANOVA was used for repeated measurements followed by Bonferroni's post-hoc test to find the limits of concordance/proximity, while the Bland and Altman method and the Intraclass Correlation Coefficient were used to establish the reliability between the pairs. The significance level adopted was p < 0.05. The results demonstrate significant differences, low levels of concordance and unsatisfactory reliability levels between Tco and Tre at all 13 analyzed moments, in addition to not showing measurement reliability when all data are used together with the 143 temperature measurements. Daily behavior analysis shows moments with similar behavior with an increase in Tco and Tre, but at other times the behavior was the opposite, with a decrease in one measurement and an increase in the other. Based on the results presented, it is not recommended to use the inner eye canthus temperature as a substitute for rectal temperature for measuring core temperature at different times of the day or in sleep-deprived individuals.
More Related Videos
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
06:33Method for Simultaneous fMRI/EEG Data Collection during a Focused Attention Suggestion for Differential Thermal Sensation
Published on: January 5, 2014
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...