Related Experiment Video
Updated: Aug 13, 2026

Using Multi-fluorinated Bile Acids and In Vivo Magnetic Resonance Imaging to Measure Bile Acid Transport
Published on: November 27, 2016
Is an intraoperative liver function assessment possible? Application of the 13C-methacetin-breath-test during major
Georgios Makridis1, Tim Reese2, Zoltán S Zádori3
1Department of Surgery, Division of Hepatobiliary and Pancreatic Surgery, Asklepios Hospital Barmbek, Hamburg, Germany; Department of General and Visceral Surgery, St. Josef's-Hospital Wiesbaden, Wiesbaden, Germany; Semmelweis University, Asklepios Campus Hamburg, Hamburg, Germany.
Background:
As prevention of posthepatectomy-liver-failure is crucial, there is need of dynamic assessment of liver function, even intraoperatively. 13C-methacetin-breath-test estimates the organ's microsomal functional capacity. This is its first intraoperative evaluation in major liver surgery.
Methods:
30 patients planed for resection of ≥3 liver segments, between March-November 2019, were prospectively enrolled in this "single-center", pilot study. Using the 13C-methacetin-breath-test, liver function was assessed four times: preoperatively, intraoperatively before and after resection and postoperatively. The resulted maximum-liver-function-capacity (LiMAx)-values and delta-over-baseline (DOB)-curves were compared, further analyzed and correlated to respective liver volumes.
Results:
The intraoperative LiMAx-values before resection were mostly lower than the preoperative ones (-11.3% ± 28%). The intraoperative measurements after resection resulted to mostly higher values than the postoperative ones (42.35% ± 46.19%). Pharmacokinetically, an interference between the two intraoperative tests was observed. There was no strong correlation between residual liver volume and function with a percentual residual-LiMAx mostly lower than the percentual residual volume (-17.7% ± 4.1%).
Conclusions:
Intraoperative application of the 13C-methacetin-breath-test during major liver resections seems to deliver lower values than the standard preoperative test. As multiple intraoperative tests interfere significantly to each other, a single intraoperative measurement is suggested. Multicentric standardized measurements could define the "normal" range for intraoperative measurements and control their predictive value.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...