Related Experiment Video
Updated: Jul 14, 2025

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Characterization of environmental radiological parameters on dose coefficient - Realistic dosimetry compared with
Amin Shahrokhi1, Tibor Kovács1
1Department of Radiochemistry and Radioecology, Research Centre for Biochemical, Environmental and Chemical Engineering, University of Pannonia, 8200, Veszprém, Hungary.
Abstract:
Radiation exposure due to all-natural sources amounts to about 2.4 mSv per year. However, this amount might be changed to over 3 mSv y-1 according to the recently introduced ICRP radon dose coefficient factor. Previously, the radon contribution to the total dose from natural sources was about 1.2 mSv y-1. However, after the latest introduced dose conversion factor by ICRP, this value could technically be increased to around 2 mSv y-1. This paper attempts to address the following questions: (i) whether reducing radon concentration to the recommended level could address concerns about radiation exposure in underground workplaces, and (ii) the effects of the difference between the epidemiological dosimetry models and realistic dose estimation. The actual dose conversion factor (DCF) was calculated using measured annual average unattached and equilibrium factors, ranging from 16 ± 9 to 25 ± 10 mSv·WLM-1. Then, the estimated inhalation dose, both from self-calculated DCF and the value reported by ICRP-137, was compared: 5.6 ± 0.7-7.6 ± 0.9 mSv y-1 and 3.3 ± 0.4-3.6 ± 0.5 mSv y-1, respectively. It can be observed that exposure to a radon concentration lower than the recommended level does not guarantee a lower dose than the recommended value. The estimated dose was at least two times greater than the dose using pre-estimated values from epidemiological dosimetry models, specifically in this case study. Further experiments in different underground working environments, excluding caves, are needed for more precise observations. It might also be time to update the data regarding the dose contribution from natural radiation sources, as the radon contribution increased according to ICRP.
Related Concept Videos
Biological Effects of Radiation
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Mechanistic Models: Compartment Models in Individual and Population Analysis
Statistical Methods for Analyzing Epidemiological Data
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...

