Related Experiment Video
Updated: Jul 20, 2026

Video Movement Analysis Using Smartphones ViMAS: A Pilot Study
Published on: March 14, 2017
Clinimetric properties of a smartphone application to measure the craniovertebral angle in different age groups and
Aafreen1, Ashfaque Khan1, Ausaf Ahmad2
1Department of Physiotherapy, Integral University, Lucknow, India.
Background:
Craniovertebral angle (CVA) alteration is a causative factor for the neck, shoulder, and temporomandibular joints disorders. Therefore, as an outcome measure for therapeutic intervention, measuring the craniovertebral angle with the Surgimap smartphone app is a cost-effective, easily accessible, and reliable tool. This study's objective was to assess the clinimetric properties of the Surgimap smartphone application with Surgimap system software to measure the Craniovertebral Angle in different age groups and positions.
Method:
Ninety subjects with neck pain were randomly allocated to aged between 18 and 30 years (Group A; n = 45) and 45-60 years (Group B; n = 45). Using the Surgimap smartphone application and Surgimap system software, the craniovertebral angle was measured objectively in the sagittal plane. Intraclass correlation coefficients were used to determine validity and reliability. Receiver operating characteristic (ROC) curves and the area under the curves (AUC) were determined to distinguish participants with and without forward head posture.
Result:
The result of this study shows that Smartphone Surgimap Application and Surgimap System Software correlate 0.95 and have p-values of 0.01 for diverse positions and ages. CVA measurement in the sitting position was significantly lower than in the standing position, regardless of methodology or age. Both positions demonstrated high intra-rater reliability, as evidenced by Intraclass Correlation Coefficients (ICC) between 0.972 and 0.991. The minimum detectable change (MDC) values ranged from 1.3 to 1.733, indicating high measurement accuracy. The smartphone application demonstrated outstanding diagnostic sensitivity (100.00% for Group A standing) and specificity (93.55% for Group B standing).
Conclusion:
The Surgimap smartphone application is a reliable and accurate method for craniovertebral angle measurement and is useful for measuring outcomes. Also standing posture was found to be better than sitting posture while measuring the CVA.
Related Concept Videos
Electronic Distance Measuring Instruments
Field Application of Global Positioning System
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
Application of Linearization and Approximation
Midpoint Rule
Trapezoidal Rule