Related Experiment Video
Updated: Jul 14, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Development and clinical application of a stability-indicating chromatography technique for the quantification of
Trusha J Purohit1, Don Laing2, Christopher Jd McKinlay2,3
1School of Pharmacy, The University of Auckland, Auckland, New Zealand.
Abstract:
Diazoxide is a potential candidate for the treatment of transitional hypoglycaemia in infants. A clinical trial is currently underway to investigate whether low-dose oral diazoxide is beneficial for severe or recurrent transitional neonatal hypoglycaemia (the NeoGluCO Study, registration ANZCTR12620000129987). The present study aimed to develop and validate the parameters for quantifying diazoxide from neonatal plasma samples, and to assess the stability of extemporaneously prepared diazoxide suspensions to support the NeoGluCO Study. To determine the plasma concentration of diazoxide, a protein precipitation mediated extraction protocol was developed, which demonstrated >94% diazoxide extraction recoveries from all samples. The method was linear over the range of 0.2-40 μg/mL (R2 > 0.9994) with a limit of quantification of 0.2 μg/mL. Accuracy of the method was within 97-106% with relative standard deviation < 6% for all samples. Diazoxide-plasma samples were stable for up to three months at -20 °C and up to 48 h when stored in the auto-sampler. Samples were stable for up to two freeze-thaw cycles, with further cycles compromising stability of diazoxide in plasma. The developed method was applied to determine chemical stability of the extemporaneously prepared diazoxide suspensions. These were stable at both 2-8 °C and 25 °C/60% RH, with 98% of diazoxide remaining after 35 days in both storage conditions. Diazoxide was successfully quantified from plasma collected from six neonates enrolled in the NeoGluCO Study, using the developed protocol. Overall, an efficient and reproducible extraction protocol was developed and validated for the estimation of diazoxide from human plasma.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
11:17Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
Related Concept Videos
Voltammetric Techniques: Linear-Scan (E vs Time)
Ion-Exchange Chromatography