Clinical Outcome after Clavicular Hook Plate Fixation for Displaced Medial-End Clavicle Fractures
Ki Bum Kim1, Young Sang Lee1, Sung Il Wang1
1Department of Orthopaedics Surgery, Jeonbuk National University Medical School, Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, Korea.
Background:
Surgery of the medial end of the clavicle remains a challenge for orthopedic surgeons. Moreover, there is no standard surgical procedure for treating displaced fractures or dislocation of the medial clavicle. Thus, the present study aimed to evaluate the safety and efficacy of using a hook plate for treating medial-end clavicular fractures and present functional outcomes.
Methods:
We retrospectively investigated 18 patients who underwent surgery with a hook plate from July 2016 to December 2021. There were 14 men and 4 women with a mean age of 57.4 years. Fracture union was assessed at follow-up by computed tomography (CT). Other outcome parameters were complications, including implant failure, infection, nonunion, osteolysis of sternal manubrium, and migration of the hook portion. Range of motion (ROM), visual analog scale (VAS), Quick Disabilities of the Arm, Shoulder and Hand (Quick DASH), and American Shoulder and Elbow Society (ASES) scores were evaluated 6 months postoperatively and at the last follow-up.
Results:
The mean operation time was 43.8 minutes (range, 35-50 minutes) and the mean follow-up was 22.8 months (range, 12-42 months). Bone union was confirmed in all cases. The mean union time was 6.2 months (range, 6-7 months). Implant removal was performed routinely according to the clinical course in 17 cases. The mean implant removal time was 10.0 months (range, 6-14 months). Clinical and functional outcomes measured at the last follow-up were significantly improved compared to those at 6 months postoperatively (p < 0.05). Regarding complications, there were 6 cases (33.3%) of osteolysis of the sternal manubrium. Although the anteroposterior length of the manubrium and hook depth showed significant differences between the non-osteolysis group and the osteolysis group (p = 0.024), ROM, VAS, Quick DASH, and ASES scores were not significantly different between the two groups (all p > 0.05).
Conclusions:
Clavicle hook plating can be a safe and effective method that can be easily applied with good outcomes if it is used with appropriate surgical planning and technique for medial-end clavicle fracture. CT scans are useful for preoperative planning and postoperative evaluation of bone union or complications.
More Related Videos
04:42Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Changes in the Appendicular Skeleton with Age
Initially, the limb buds consist of a core of mesenchyme covered by a layer of ectoderm. The ectoderm at the end of the limb bud thickens to form a narrow crest called the apical ectodermal ridge. This ridge stimulates the underlying...
