Comparison of optimization techniques for the Monte Carlo simulation of clearance monitors
Federico Alejandro Geser1, Malgorzata Magdalena Kasprzak1, Sabine Mayer1
1Department of Radiation Safety and Security, Paul Scherrer Institute (PSI), Villigen PSI CH-5232, Switzerland.
Abstract:
In this work, simulations of the clearance monitor HWM-1800 (Ludlum GmbH, Hamburg) with the Monte Carlo (MC) code FLUKA were performed and optimized. Nowadays, clearance monitors are being widely implemented for decommissioning activities in nuclear reactors and particle accelerator facilities. For every situation, a different calibration is typically needed, depending on the material composition of the samples to be released, their volume and the expected radionuclides. For this reason, MC simulations present a practical tool to obtain information on the capabilities of clearance monitors for different configurations. Early models of clearance monitors worked as counters, providing an energy-integrated value of the measured net count rates. However, modern devices have a multi-channel analyzer, which allows constructing pulse-height spectra. The results of the MC simulations were optimized for both of the described situations: comparing the integrated net count rates and performing a spectral analysis. The performance of both methodologies is evaluated in terms of their discrepancy with the experimentally measured values, and the possible improvements for the optimization with spectral analysis are further discussed.
More Related Videos
Related Concept Videos
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Clearance Models: Noncompartmental Models
The noncompartmental approach capitalizes on extensive sampling data, correlating the volume of distribution to systemic exposure and the administered dosage. This method enables...
Clearance Models: Compartment Models
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...