Uncertainties associated with direct thyroid measurements using an NaI(Tl) survey meter: the effect of anatomical
Masato Narita1, Kotaro Tani2, Naoaki Kunishima3
1Naka Fusion Institute, National Institutes for Quantum Science and Technology, Ibaraki, Japan.
Abstract:
Photon detectors utilised for direct thyroid measurements to determine the radioiodine content in the thyroid are normally calibrated using a phantom that mimics the human neck, including the thyroid. However, such measurements are necessarily subject to uncertainty because of the difference between the phantom and the real human subject and also the morphological differences among individuals. In this study, personal voxel phantoms were created from magnetic resonance images of the necks of 24 adult volunteers (15 males and 9 females), and numerical simulations using these phantoms were performed to examine the variation in a conversion factor (131I kBq in the thyroid per μSv h-1) for a conventional NaI(Tl) survey meter among the individuals and also to confirm the suitability of reference Japanese voxel phantoms as a calibration standard for such measurements. As a result, it was found that the conversion factor obtained from the reference Japanese male (female) phantom was 1.29 (1.18) times larger than the average conversion factor for the male (female) subjects, suggesting that the conversion factors of the reference Japanese adult male and female phantoms would generally overestimate the 131I thyroidal contents and that the thyroid volume would be one of the factors influencing the conversion factor. This study also revealed a wide difference in the thyroid volume among individuals, which would be of concern when performing specific dose assessments for heavily exposed persons.
More Related Videos
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...