Related Experiment Video
Updated: Jul 13, 2025

Fabricating Cotton Analytical Devices
Published on: August 30, 2016
Reusing sterile cotton fabric barriers in the clinical practice: an observational and longitudinal study
Berendina Elsina Bouwman1,2, Dayane de Melo Costa3, Francesco Tessarolo4
1Universidade Federal de Jataí, Jataí, GO, Brasil.
Objective:
to analyze the physical and biological barrier characteristics of cotton fields used as a sterile barrier system after multiple use and processing cycles in the clinical practice.
Method:
an observational and longitudinal study to monitor and evaluate 100% cotton fabric used as a sterile barrier system in a medium-sized hospital. Samples were collected before use (after three washes) and at three, six, nine, 12 and 15 months of use and evaluated for the number, thickness and integrity of threads, weight, water absorption and wet penetration by microorganisms.
Results:
after 85 washes, the number of threads remained unchanged, and the shredded fibers and the water volume absorbed were increased. The microbiological test using the German standard methodology obtained a negative result and wet penetration by microorganisms did not show significant changes over time, although a percentage of the microbial cells passed through the double-layer samples.
Conclusion:
the physical properties of 100% cotton used as a sterile barrier system changed with use/processing cycles; however, these alterations did not significantly interfere with the results obtained by the tests performed on the microbiological barrier up to 85 washes. (1) Clinical use and processing exert an impact on the sterile fabric barrier system. (2) There was weight loss, reduction in size and increase in water absorption volume. (3) The longer the use, the more loose fibers. (4) Penetration by microorganisms did not increase over the 15 months of the study. (5) The physical changes of the fabric did not interfere with the fabric barrier efficiency.
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Observational Studies
There are three types of observational studies – Prospective, retrospective, and cross-sectional.
Prospective Study
Prospective studies, also known as longitudinal or cohort studies, are carried out by collecting future data from groups sharing similar characteristics. One...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...