Related Experiment Video
Updated: Jul 13, 2025

Adult Mouse Venous Hypertension Model: Common Carotid Artery to External Jugular Vein Anastomosis.
Published on: January 27, 2015
A Novel Window Into Human Vascular Remodeling and Diagnosing Carotid Flow Impairment: The Petro-Occipital Venous
Wenjie Yang1, Kevin Sam1, Ye Qiao2
1Department of Diagnostic Radiology & Nuclear Medicine University of Maryland School of Medicine Baltimore MD.
Abstract:
Background Adaptive arterial remodeling caused by flow reduction from downstream stenosis has been demonstrated in animal studies. The authors sought to determine whether inward remodeling from downstream stenosis also occurs in humans and is detectable by ex vacuo expansion of the Rektorzik venous plexus (RVP) surrounding the petrous internal carotid artery. Methods and Results The authors analyzed 214 intracranial magnetic resonance imaging examinations that included contrast-enhanced vessel wall imaging. RVP symmetry was qualitatively assessed on vessel wall imaging. RVP thickness (RVPT) was measured on the thicker side if asymmetric or randomly assigned side if symmetric. Maximum stenosis (M1 or intracranial internal carotid artery) was measured. Posterior communicating artery and A1 diameters (>1.0 mm and 1.5 mm, respectively) defined adequate collateral outflow when proximal to the stenosis. Seventy-two patients had stenosis downstream from RVPT measurements. For those without adequate outflow (38 of 72), 95.0% with RVPT ≥1.0 mm had ≥50% stenosis compared with only 5.6% with RVPT <1.0 mm. For these 72 patients, higher RVPT (RVPT ≥1.0 mm versus <1.0 mm) and absent adequate outflow were associated with greater downstream stenosis (P<0.001) using multivariate regression. For patients with downstream stenosis without adequate outflow, asymmetric RVP thickening was associated with greater ipsilateral stenosis (P<0.001, all had ≥46% stenosis) when stenosis was unilateral and greater differences in stenosis between sides (P=0.005) when stenosis was bilateral. Conclusions Inward internal carotid artery remodeling measured by RVPT or RVP asymmetry occurs as downstream stenosis approaches 50%, unless flow is preserved through a sufficiently sized posterior communicating artery or A1, and may serve as a functional measure of substantial flow reduction from downstream stenosis.
More Related Videos
05:20A Murine Model of Ischemic Retinal Injury Induced by Transient Bilateral Common Carotid Artery Occlusion
Published on: November 12, 2020
11:00A Model of Disturbed Flow-Induced Atherosclerosis in Mouse Carotid Artery by Partial Ligation and a Simple Method of RNA Isolation from Carotid Endothelium
Published on: June 22, 2010
Related Concept Videos
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
The Arch of Aorta
Encircling the heart, the coronary arteries form a ring-like structure before...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....