This study introduces TraHGR, a novel hybrid deep learning model using transformers for improved hand gesture recognition (HGR) from surface electromyogram (sEMG) signals. TraHGR significantly enhances prosthesis control accuracy by effectively extracting features from sparse sEMG data.
Area of Science:
- Biomedical Engineering
- Machine Learning
- Rehabilitation Technology
Background:
- Deep learning for hand gesture recognition (HGR) using surface electromyogram (sEMG) signals shows promise for advanced myoelectric prostheses.
- Classifying hand movements from sparse multichannel sEMG signals remains challenging for current deep learning models, often limited by single-model approaches that struggle with representative feature extraction.
Purpose of the Study:
- To address the limitations of existing deep learning models in HGR using sEMG signals.
- To propose a novel hybrid deep learning framework, Transformer for Hand Gesture Recognition (TraHGR), that leverages transformer architecture for improved feature extraction and classification accuracy.
- To evaluate the performance of TraHGR against state-of-the-art methods on a standard dataset.
Main Methods:
- Developed a hybrid deep learning architecture, TraHGR, integrating parallel processing paths within a transformer framework.
- The architecture features a fusion center using a linear layer to combine features from parallel modules.
- Evaluated TraHGR on the Ninapro DB2 dataset, comprising sEMG signals from 40 users performing 49 distinct gestures under real-life conditions.
Main Results:
- The TraHGR architecture achieved high recognition accuracies: 86.00% (DB2, 49 gestures), 88.72% (DB2-B, 17 gestures), 81.27% (DB2-C, 23 gestures), and 93.74% (DB2-D, 9 gestures).
- These results represent significant improvements over the state-of-the-art, with accuracy gains of 2.30%, 4.93%, 8.65%, and 4.20% for the respective datasets.
- Experiments confirmed the superior performance of the hybrid TraHGR architecture compared to its individual parallel paths.
Conclusions:
- The proposed TraHGR hybrid framework effectively addresses the challenges of HGR using sparse sEMG signals.
- The transformer-based architecture demonstrates superior capability in extracting representative features, leading to significant accuracy improvements in myoelectric prosthesis control.
- TraHGR represents a substantial advancement in the field, offering enhanced performance for advanced prosthetic limb applications.