Related Experiment Video
Updated: Jul 13, 2025

Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Evaluation of brachial plexus stiffness in different arm and head positions by sonoelastography
Muhammet Ahmet Karakaya1, Kamil Darcin1, Ilker Ince2
1Department of Anesthesiology and Reanimation, Koc University Hospital, Istanbul, Turkey.
Abstract:
Intraoperative positioning-related nerve injuries, particularly those affecting the brachial plexus, are concerning complications believed to arise from stretching and/or compression of peripheral nerves. Although sonoelastography, a new ultrasound technology, is emerging as a valuable tool in the musculoskeletal system, its utility in evaluating peripheral nerves remains unclear. This study aimed to utilize sonoelastography to assess the brachial plexus during surgery, specifically investigating changes in its stiffness values in relation to different head and arm positions. In this prospective cohort study, bilateral brachial plexuses of 8 volunteers in 3 different positions were enrolled. Using a high-frequency linear probe, the stiffness of the brachial plexus was quantitatively measured in kilopascals (kPa) under 3 different positions: neutral, head rotated, and head rotated with arm hyperabducted. Intra-class agreement was evaluated. The stiffness of the brachial plexus was 7.39 kPa in the neutral position (NP), 10.28 kPa with head rotation, and 17.24 kPa when the head was turned, and the ipsilateral arm was hyperabducted. Significant increases were observed in stiffness values when the head was turned, whether ipsilaterally or contralaterally, and during hyperabduction of the arm while the head was turned (for all P < .001). Strong intra-class correlations were found for the measurements of stiffness values (ICC = 0.988-0.989; P < .001; Cronbach Alpha = 0.987-0.989). Sonoelastography revealed significant increases in the stiffness of the brachial plexus with various head rotations and arm positions compared to the neutral state. These findings suggest that sonoelastography could potentially serve as a valuable tool for assessing the risk of brachial plexus injury during surgery and for guiding optimal patient positioning. Further research with larger sample sizes is needed to establish definitive clinical applications.
More Related Videos
06:51Methods for In Vivo Biomechanical Testing on Brachial Plexus in Neonatal Piglets
Published on: December 19, 2019
09:14Surface Electromyographic Biofeedback as a Rehabilitation Tool for Patients with Global Brachial Plexus Injury Receiving Bionic Reconstruction
Published on: September 28, 2019
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Strain and Elastic Modulus
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Spinal Nerves: Plexus I
The Cervical Plexus
The cervical plexus, formed by the anterior rami of the first four...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: