Related Experiment Video
Updated: Jul 24, 2026

A Colorimetric Method for Measuring Iron Content in Plants
Published on: September 7, 2018
Analysis of the iron states in iron-containing pharmaceutical products using Mössbauer spectroscopy
Irina V Alenkina1, Andrey V Chukin1, Gregory Leitus2
1Institute of Physics and Technology, Ural Federal University, Ekaterinburg 620002, Russian Federation.
Abstract:
Iron-containing pharmaceuticals, namely: (i) PreNatal with ferrous fumarate, (ii) Tardyferon® with ferrous sulfate, (iii) Fenules with water free ferrous sulfate, (iv) Iron Complex with iron glycinate, citrate, (v) Gentle Iron, (vi) Hema-Plex® and (vii) Iron Bisglycinate with iron (ferrous) bisglycinate chelate (iron compounds are given as declared by the manufactures) were studied by 57Fe Mössbauer spectroscopy with X-ray diffraction and magnetization measurements for analysis of the iron state. The obtained results demonstrate that the iron compound announced by the manufacturer in each pharmaceutical is not homogeneous and exists as some modifications of this compound or results of its transformation/oxidation probably due to its instability. The presence of ferrous and ferric compounds is observed, and the relative ferric iron fractions are roughly determined for each pharmaceutical product. This analysis clearly shows the differences between the iron compounds proclaimed by the manufacturers and those obtained by Mössbauer spectroscopy. That justifies as to why this technique should be used for the control and analysis of the iron-containing pharmaceuticals.
More Related Videos
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry CE-ICP-MS for Quantification of Iron Redox Species FeII, FeIII
Published on: May 4, 2020
04:40Dynamic Light Scattering Analysis for the Determination of the Particle Size of Iron-Carbohydrate Complexes
Published on: July 7, 2023
Related Concept Videos
Qualitative Analysis
For instance, group IV...
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human eye.
Complexometric Titration: Overview