Related Experiment Video
Updated: Jul 13, 2025

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Nonlinear Dynamic Analysis of Pilotis Structures Supported by Drift-Hardening Concrete Columns
Shiyu Yuan1, Takashi Takeuchi1, Yuping Sun1
1Department of Architecture, Graduate School of Engineering, Kobe University, Kobe 657-8501, Japan.
Abstract:
Pilotis structures consisting of upper concrete bearing-walls and a soft first story have been well used in residential and office buildings in urban areas to primarily accommodate parking lots. In this research, drift-hardening concrete (DHC) columns developed by the authors are proposed to form the pilotis story with the aims of reducing its excessive residual drift caused by stronger earthquakes than anticipated in current seismic codes, mitigating damage degree, and enhancing resilience of the pilotis story. Nonlinear dynamic analysis was conducted to investigate the dynamic response characteristics of the wall structures supported by DHC columns. To this end, two sample six-story one-bay pilotis structures were designed following the current Japanese seismic design codes and analyzed. One sample structure is supported by ductile concrete (DC) columns, while the other is supported by DHC columns, which have the same dimensions, steel amount, and concrete strength as DC columns. Three representative ground motions were adopted for the nonlinear dynamic analysis. The analytical parameter was the amplitude of peak ground acceleration (PGA), scaled by the peak ground velocity (PGV) ranging between 12.5 cm/s and 100 cm/s with an interval of 12.5 cm/s. The analytical results have revealed that the residual drift of the pilotis story composed of DHC columns could be reduced to nearly zero under selected earthquakes scaled up to PGV = 100 cm/s, owing to not only the inherent self-centering ability of DHC columns but also the shake-down effect, which implies that the use of DHC columns can greatly enhance resilience of pilotis structures under strong earthquake inputs and promote its application in the buildings located in strong earthquake-prone regions. The maximum inter-story shear forces (MISFs) along the building height of the two models are also compared.
Related Concept Videos
Effects of Creep
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Design of Columns under a Centric Load
Euler's formula is applicable under the assumption that the column is a perfect, straight, homogenous prism, and it is operating...
Design of Columns under an Eccentric Load
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Euler's Formula for Pin-Ended Columns
To calculate the critical load,...