Study on the Dynamic Mechanical Properties of Ultrahigh-Performance Concrete under Triaxial Constraints
Wei Zhang1, Jize Mao1, Xiao Yu2
1College of Aerospace and Civil Engineering, Harbin Engineering University, Harbin 150001, China.
Abstract:
To confirm the effect of confining pressure on the dynamic mechanical behavior of ultrahigh-performance concrete (UHPC), this study used a true triaxial split Hopkinson pressure bar test system to perform dynamic compression tests on UHPC under triaxial constraints. The confining pressure range considered was 5~10 MPa, the strain rate range was 35~80 s-1, and the steel fiber contents were 0.5%, 1% and 2%. The three-dimensional dynamic engineering stress-strain relationship and equivalent stress-strain relationship of UHPC under different confining pressures and different strain rates were obtained and analyzed in detail. The results show that under the confinement condition, the dynamic peak axial stress-strain and dynamic peak lateral stress-strain of UHPC have strong sensitivity to the strain rate. In addition, the dynamic peak lateral stress-strain is more sensitive to the confining pressure than the dynamic axial stress. An empirical strength enhancement factor (DIFc) that considers the strain rate effect and confining pressure was derived, and the impact of the coupling between the enhancement caused by the confining pressure and the strain rate effect on the dynamic strength of the UHPC under triaxial confinement was discussed. A dynamic strength failure criterion for UHPC under triaxial constraint conditions was established.
More Related Videos
11:07Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Relation Between Tensile Strength and Compressive Strength of Concrete
Elasticity in Concrete
Impact Strength of Concrete