Related Experiment Video
Updated: Jul 13, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
An Orthogonal Test Study on the Preparation of Self-Compacting Underwater Non-Dispersible Concrete
Haibin Geng1, Huijuan Wang2, Xiaoke Li1,3
1Collaborative Innovation Center for Efficient Utilization of Water Resources, International Joint Research Lab for Eco-Building Materials and Engineering of Henan, North China University of Water Resources and Electric Power, Zhengzhou 450045, China.
Abstract:
To ensure a limited washout loss rate and the self-compaction of underwater concrete, the mix proportion design of underwater non-dispersible concrete is a key technology that has not been completely mastered. In view of this aspect, an orthogonal test study was carried out in this paper on the workability, washout resistance, and compressive strength of underwater non-dispersible concrete. Six factors with five levels were considered, which included the water/binder ratio, the sand ratio, the maximum particle size of the coarse aggregate, the content of the dispersion resistance agent, the content of superplasticizer, and the dosage of fly ash. Using a range and variance analysis, the sensitivity and significance of these factors were analyzed on the slump and slump-flow, the flow time, the washout loss rate, the pH value, and the compressive strength at the curing ages of 7 days and 28 days. The results indicated that the water/binder ratio and the content of the dispersion resistance agent were strong in terms of their sensitivity and significance on the workability and washout resistance, and the water/binder ratio and the dosage of fly ash were strong in terms of their sensitivity and significance on the compressive strength. With the joint fitness of the test results, formulas for predicting the slump-flow, washout loss rate, and compressive strength of underwater non-dispersible concrete were proposed considering the main impact factors.
More Related Videos
05:38Production and Analysis of Sporosarcina pasteurii Biocement Bricks Using Custom 3D-Printed Molds for Unconfined Compression Tests
Published on: March 7, 2025
10:27A Uniaxial Compression Experiment with CO2-Bearing Coal Using a Visualized and Constant-Volume Gas-Solid Coupling Test System
Published on: June 12, 2019
Related Concept Videos
Testing Water Quality
Compacting Factor test
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
Permeability of Concrete
Non-destructive Tests for Concrete Strength
Design Example: Managing Concrete Workability
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...