Related Experiment Video
Updated: Jul 13, 2025

Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
Effect of Corrosive Environment on the High-Cycle Fatigue Behavior of Reinforced Concrete by Epoxy Resin:
1Department of Transport, Academy of Engineering, RUDN University, 6 Miklukho-Maklaya Street, Moscow 117198, Russia.
Abstract:
Large engineering structures made of various materials, including concrete (e.g., bridges, dams, buildings, and multilevel car parks), steel (e.g., power towers, ships, and wind turbines), or others, are often subjected to severe vibration, dynamic, and cyclic loads, which lead to crack initiation, crack growth, and finally structural failure. One of the effective techniques to increase the fatigue life of such structures is the use of reinforced materials. In the meantime, environmental factors, such as corrosion caused by corrosive environments, also affect the fatigue behavior of materials. Therefore, the main purpose of this paper is to study the influence of corrosive environment on the high-cycle fatigue (HCF) behavior of concrete reinforced by epoxy resin. For this purpose, five corrosive environments with different intensities, including fresh air, water: W, sea water: SW, acidic: AC, and alkaline: AL, were considered and the laboratory samples of conventional concrete (CC) and polymer concrete (PC) were immersed in them for one month. Next, axial fatigue tests were performed under compressive-compressive loading with a frequency of 3 Hz on cylindrical specimens. Moreover, to achieve reliable results, for each stress amplitude, the fatigue test was repeated three times, and the average number of cycles to failure was reported as the fatigue lifetime. Finally, the stress-life cycle (S-N) curves of different states were compared. The results showed that polymer concrete can resist well in corrosive environments and under cyclic loads compared to the conventional concrete, and in other words, the epoxy resin has performed its task well as a reinforcer. The results of fatigue tests show that the load bearing range of 10 tons by CC has reached about 18 tons for PC, which indicates an 80% increase in fatigue strength. Meanwhile, the static strength of samples in the vicinity of fresh air has only improved by 12%.
More Related Videos
10:24Applicability Analysis of Assessment Methods for Morphological Parameters of Corroded Steel Bars
Published on: November 1, 2018
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Fatigue Strength of Concrete
Acid Attack on Concrete
The rate at which hydrogen...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Effect of Sea Water on Concrete
Concrete in areas between tide marks,...
Fiber Reinforced Concrete