Related Experiment Video
Updated: Jul 22, 2026

Mechano-Node-Pore Sensing: A Rapid, Label-Free Platform for Multi-Parameter Single-Cell Viscoelastic Measurements
Published on: December 2, 2022
Dynamic Characterization of a Low-Cost Fully and Continuously 3D Printed Capacitive Pressure-Sensing System for
Andrew T Gothard1, Jacob W Hott1, Steven R Anton1
1Dynamic and Smart Systems Laboratory, Department of Mechanical Engineering, Tennessee Technological University, Cookeville, TN 38505, USA.
Abstract:
In orthopedics, the evaluation of footbed pressure distribution maps is a valuable gait analysis technique that aids physicians in diagnosing musculoskeletal and gait disorders. Recently, the use of pressure-sensing insoles to collect pressure distributions has become more popular due to the passive collection of natural gait data during daily activities and the reduction in physical strain experienced by patients. However, current pressure-sensing insoles face the limitations of low customizability and high cost. Previous works have shown the ability to construct customizable pressure-sensing insoles with capacitive sensors using fused-deposition modeling (FDM) 3D printing. This work explores the feasibility of low-cost fully and continuously 3D printed pressure sensors for pressure-sensing insoles using three sensor designs, which use flexible thermoplastic polyurethane (TPU) as the dielectric layer and either conductive TPU or conductive polylactic acid (PLA) for the conductive plates. The sensors are paired with a commercial capacitance-to-voltage converter board to form the sensing system. Dynamic sensor performance is evaluated via sinusoidal compressive tests at frequencies of 1, 3, 5, and 7 Hz, with pressure levels varying from 14.33 to 23.88, 33.43, 52.54, and 71.65 N/cm2 at each frequency. Five sensors of each type are tested. Results show that all sensors display significant hysteresis and nonlinearity. The PLA-TPU sensor with 10% infill is the best-performing sensor with the highest average sensitivity and lowest average hysteresis and linearity errors. The range of average sensitivities, hysteresis, and linearity errors across the entire span of tested pressures and frequencies for the PLA-TPU sensor with 10% infill is 11.61-20.11·10-4 V/(N/cm2), 11.9-31.8%, and 9.0-22.3%, respectively. The significant hysteresis and linearity error are due to the viscoelastic properties of TPU, and some additional nonlinear effects may be due to buckling of the infill walls of the dielectric.
More Related Videos
10:28Sensitivity Enhancement of Soft Capacitive Pressure Sensors Using a Solvent Evaporation-Based Porosity Control Technique
Published on: March 24, 2023
05:57Author Spotlight: Microfluidic Channel-Based Soft Electrodes and Their Application in Capacitive Pressure Sensing
Published on: March 17, 2023
Related Concept Videos
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific weight or...
Fluid Pressure over Flat Plate of Constant Width
The resultant force...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Pressure Gauges
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Static, Stagnation, Dynamic and Total Pressure