Comparing Accuracy of Helicobacter pylori Identification Using Traditional Hematoxylin and Eosin-Stained Glass Slides
Wei Chen1, Jennifer Ziebell1, Vidya Arole1
1Department of Pathology, The Ohio State University Wexner Medical Center, Columbus, Ohio.
Abstract:
With advancements in the field of digital pathology, there has been a growing need to compare the diagnostic abilities of pathologists using digitized whole slide images against those when using traditional hematoxylin and eosin (H&E)-stained glass slides for primary diagnosis. One of the most common specimens received in pathology practices is an endoscopic gastric biopsy with a request to rule out Helicobacter pylori (H. pylori) infection. The current standard of care is the identification of the organisms on H&E-stained slides. Immunohistochemical or histochemical stains are used selectively. However, due to their small size (2-4 μm in length by 0.5-1 μm in width), visualization of the organisms can present a diagnostic challenge. The goal of the study was to compare the ability of pathologists to identify H. pylori on H&E slides using a digital platform against the gold standard of H&E glass slides using routine light microscopy. Diagnostic accuracy rates using glass slides vs digital slides were 81% vs 72% (P = .0142) based on H&E slides alone. When H. pylori immunohistochemical slides were provided, the diagnostic accuracy was significantly improved to comparable rates (96% glass vs 99% digital, P = 0.2199). Furthermore, differences in practice settings (academic/subspecialized vs community/general) and the duration of sign-out experience did not significantly impact the accuracy of detecting H. pylori on digital slides. We concluded that digital whole slide images, although amenable in different practice settings and teaching environments, does present some shortcomings in accuracy and precision, especially in certain circumstances and thus is not yet fully capable of completely replacing glass slide review for identification of H. pylori. We specifically recommend reviewing glass slides and/or performing ancillary stains, especially when there is a discrepancy between the degree of inflammation and the presence of microorganisms on digital images.
More Related Videos
08:40Quantitation of Protein Expression and Co-localization Using Multiplexed Immuno-histochemical Staining and Multispectral Imaging
Published on: April 8, 2016
07:32Author Spotlight: Investigating Immune Cell Dynamics in the Tumor Microenvironment — Challenges and Innovations in Cancer Prognosis
Published on: April 12, 2024