Related Experiment Video
Updated: Jul 13, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
A novel fusion method for X-ray phase contrast imaging based on fast adaptive bidimensional empirical mode
Zonghan Tian1, Siwei Tao1, Ling Bai1
1State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science & Engineering, Zhejiang University, Hangzhou, China.
Backgrounds:
X-ray phase contrast imaging (XPCI) can separate the attenuation, refraction, and scattering signals of the object. The application of image fusion enables the concentration of distinctive information into a single image. Some methods have been applied in XPCI field, but wavelet-based decomposition approaches often result in loss of original data.
Objective:
To explore the application value of a novel image fusion method for XPCI system and computed tomography (CT) system.
Methods:
The means of fast adaptive bidimensional empirical mode decomposition (FABEMD) is considered for image decomposition to avoid unnecessary information loss. A parameter δ is proposed to guide the fusion of bidimensional intrinsic mode functions which contain high-frequency information, using a pulse coupled neural network with morphological gradients (MGPCNN). The residual images are fused by the energy attribute fusion strategy. Image preprocessing and enhancement are performed on the result to ensure its quality. The effectiveness of other image fusion methods has been compared, such as discrete wavelet transforms and anisotropic diffusion fusion.
Results:
The δ-guided FABEMD-MGPCNN method achieved either the first or second position in objective evaluation metrics with biological samples, as compared to other image fusion methods. Moreover, comparisons are made with other fusion methods used for XPCI. Finally, the proposed method applied in CT show expected results to retain the feature information.
Conclusions:
The proposed δ-guided FABEMD-MGPCNN method shows potential feasibility and superiority over traditional and recent image fusion methods for X-ray differential phase contrast imaging and computed tomography systems.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Imaging
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...