Abstract:
In pharmaceutical analysis using a high-performance liquid chromatography (HPLC) system, repeatability assessment is significant to obtain reliable and precise quantitative results. The purpose of the present study is to experimentally show the statistical reliability of a relative standard deviation (RSD) of peak area estimated by a chemometric tool based on probability theory, called the function of mutual information (FUMI) theory, which stochastically provided an RSD of peak area and SD of baseline areas with width k (s(k)) from noises and a signal on a single chromatogram. An ultra-high-performance liquid chromatography with ultraviolet detection (UHPLC-UV) for determining ergosterol was applied as an example of the repeatability assessment. In addition, the statistical reliability of an RSD of peak area in the UHPLC-UV system was certified according to a chi-square (χ2) distribution. The 712 values of s(k) were experimentally obtained from a data series of 1001 points in the noise regions of 712 chromatograms. The histogram of χ2 of s(k) was well-fitted to the χ2 distribution curve (freedom degree, ν = 50), indicating that the statistical reliability of an RSD of the peak area in the UHPLC-UV estimated by the FUMI theory (n = 1) was equivalent to that estimated by 50 runs of chromatographic measurements.
Related Concept Videos
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Chromatographic Methods: Terminology
Data Validation
Key parameters for method validation include:
Standard Deviation of Calculated Results
A broad Gaussian distribution curve has a wider standard deviation, representing a data set with...
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...