Related Experiment Video
Updated: Jul 13, 2025

Making MR Imaging Child's Play - Pediatric Neuroimaging Protocol, Guidelines and Procedure
Published on: July 30, 2009
Using the non-distortion IVIM to reduce the need for contrast agents in nasopharyngeal MRI
Rui Chen1, Huifen Ye1, Zhigang Wu2
1Department of Radiology, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou 510080, China; Guangdong Provincial Key Laboratory of Artificial Intelligence in Medical Image Analysis and Application, Guangzhou 510080, China.
Background:
Patients with nasopharyngeal carcinoma (NPC) who undergo longitudinal follow-up contrast-enhanced MRI are at risk of developing gadolinium deposition in their neural tissue, which may potentially harm them. Therefore, for these patients, a non-contrast-enhanced method is potentially beneficial as an alternative approach to predict enhancement in T1-weighted imaging (CE-T1WI). The traditional intravoxel incoherent motion (IVIM) is one of the non-contrast-enhanced methods; however, the severe distortion and signal loss limit its application in patients with NPC. The present study aimed to investigate whether non-distortion IVIM could reduce the need of CE-T1WI in the follow-up of patients with NPC.
Methods:
The patients with NPC underwent Turbo Spin-echo MVXD diffusion-weighted imaging-based IVIM (non-distortion IVIM) from November 2021 to May 2022. Firstly, thirty patients with NPC were underwent both non-distortion IVIM and traditional IVIM. The distortion rate (DR) of the non-distortion IVIM was compared with the traditional IVIM. Then, twenty-one NPC patients with tumors (areas >50mm2) were included and correlation coefficient analysis was used to assess the relationship between their non-distortion IVIM and CE-T1WI. Linear regression analysis was performed to determine whether non-distortion IVIM predictors could predict CE-T1WI.
Results:
The correlation was observed between the parameter f of the non-distortion IVIM and the enhancement ratio of CE-T1WI (r = 0.543, P = 0.011). Moreover, the linear regression analysis revealed that f was an independent IVIM predictor of CE-T1WI in patients with NPC (P = 0.011). The DR of the non-distortion IVIM was significantly smaller than that of the traditional IVIM (0.12 ± 0.05 vs 0.48 ± 0.16, P < 0.001).
Conclusions:
In patients with NPC, non-distortion IVIM showed potential clinical benefits to reduce the need for contrast agents, and it can independently predict the enhancement ratio.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT