Related Experiment Video
Updated: Jul 13, 2025

Electrochemiluminescence Assays for Human Islet Autoantibodies
Published on: March 23, 2018
Palpitation in women with silicone breast implants: association with autoantibodies against autonomic nervous system
Tal Elroy1, Gilad Halpert2, Avishai M Tsur3,4,5
1Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel. elroytal@gmail.com.
Abstract:
We explored a possible association between palpitation manifestation in women with silicone breast implants (SBIs) with circulating level of autoantibodies directed against autonomic nervous system (ANS) receptors. The study was conducted in 93 women with SBIs who arrived to our clinic with diverse symptoms thought to be associated with their implants. Titers of 11 various autoantibodies were measured in the sera of women with SBIs who experienced palpitations (Palpitations, n = 47), did not experience palpitations (Non, n = 46), and healthy women (Control, n = 36). A significant reduction in anti-α2-adrenergic receptor (A2AR, P = 0.035), anti-β2-adrenergic receptor (B2AR, P = 0.027), antimuscarinic receptors M1R (P = 0.048), and anti-M2R (P = 0.039) autoantibodies was found in the 'Palpitations' group as compared with the 'Non' group. Anti-B2AR (P = 0.042), anti-M1R (P = 0.017), and anti-M2R (P = 0.0015) autoantibodies were also significantly reduced in 'Palpitations' as compared with the 'Control' group. Our study shows possible association between autoantibodies directed against ANS receptors, with existing complaints of palpitations in women with SBIs.
Related Concept Videos
Gastritis-II: Pathophysiology
In acute gastritis, the gastric mucosa becomes swollen and red and undergoes superficial erosion. Superficial ulceration may lead to bleeding.
In chronic gastritis, persistent or repeated insults lead to chronic inflammatory changes and, eventually, thinning or atrophy of the gastric tissue.
Gastritis can stem from various causes, each...
Pericarditis II: Clinical Features and Diagnostic Tests
Cross-reactivity
Angina III: Clinical Manifestations and Assessment
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...

