Arterial spin labeling MRI using spiral acquisitions and concurrent field monitoring
1Institute for Biomedical Engineering, University and ETH Zürich, Zürich, Switzerland; Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Switzerland.
Abstract:
Perfusion MRI based on arterial spin labeling (ASL) has intrinsically very low signal-to-noise ratio (SNR). Signal acquisition at shorter echo times (TE) is necessary to boost the SNR of the ASL images. Spiral trajectories provide substantially shorter TE yielding increased SNR and are among the fastest k-space sampling schemes to encode a given field of view and resolution. Moreover, they provide approximately isotropic point-spread functions and inherent refocusing of motion- and flow-induced phase errors. However, the efficiency of the spiral acquisitions in ASL-MRI has been limited because these advantages are counterbalanced by practical technical challenges. This is because spiral acquisitions are highly sensitive to encoding deficiencies such as static off-resonance in the main magnetic field manifested as blurring artifacts in the image. Moreover, deviation of the gradient fields from the nominal waveforms due to the imperfection of the employed hardware critically limits the practical utilization of spiral trajectories. In this work, I provide single- and multiple-shot spiral ASL images that are robust against typical spiral encoding drawbacks enabled by deploying a comprehensive signal model involving static off-resonance and coil sensitivity maps and actual B0 and gradient field dynamics up to third order in space. The spiral ASL signal acquisition was concurrently monitored using a 3rd order dynamic field camera based on NMR field probes. The reconstructed ASL images at 3 mm and 2 mm in-plane resolution associating with the monitored field dynamics and the static off-resonances exhibited strongly reduced blurring- and aliasing artifacts and distortion. Concurrent field monitoring also enables to account for quasi-static B0 drifts by encompassing the parametric input data with consistent encoding geometry and physiological field fluctuations. In conclusion, concurrent field monitoring in spiral ASL acquisition largely overcomes traditional vulnerability of spiral trajectories in practice providing high quality ASL images with increased SNR, speed and motion robustness.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...